SM Health Care
Packing: 1 UNIT
Benefusion Syringe Pump SP1
Regular price
MYR 3,800.00
Shipping calculated at checkout.
BENEFUSION SYRINGE PUMP SP1
S-A-L06-SP1
Friendliness
- "One Hand Operation" and intuitive keypad
- Compact and lightweight design for easy carrying
- Long runtime battery, suitable for emergency and patient transfer
Safety
- High accuracy : ± 2% satisfying neonatal use
- Fast start function against start delay due to friction
- Dynamic pressure detection, anti bolus
- IP24 water and dust protection, support cleaning with Water
Connectivity
- Ambulance Support
- WiFi Connection available
- Dock Support
TECHNICAL SPECIFICATION
-
SPEFICICATION & FUNCTION
- Dimension: 330 x 126 x 110 mm
- Syringe Size : 5, 10, 20, 30, 50/60ml
- Infusion mode : Rate Mode
- Flow rate range : 5ml syringe: (0.1~150) ml/h; 10ml syringe: (0.1~300) ml/h; 20ml syringe: (0.1~600) ml/h30ml syringe: (0.1~900) ml/h; 50ml/60ml syringe: (0.1~1500) ml/h
- Accumulated volumn : 0.1~9999 ml, increment is 0.1 ml
- VTBI : 0.1~9999 ml, increment is 0.1 ml
- Increment : 0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h
- Accuracy : Flow rate≥1 ml/h: Accuracy ≤ ±2%; Flow rate<1 ml/h: Accuracy ≤ ±3%
- KVO rate : 0.5 ml/h, unadjustable
- Bolus / Purge Rate : 0.10-1500ml/h (depending on syringe size)
- Occlusion : Low 300±75 mmHg (40kPa) Medium 525±75 mmHg (70kPa)
High 900±135 mmHg (120 kPa) - Screen : 2.5" LCD monochrome screen, 132 x 32 Pixels
- Titration : Yes
- Keypad Lock : Yes
- Pause : Yes
- Automatic Recognition of Syringe Size: Yes
- Self Test System : Yes
- Weight : <1.8kg (including clamp)
- Dock : Supported
- Handle : Included
- Mouting type : Standard;p Verticle pole, Optional : Horizontal Pole
- Alarm Volumn: 1 - 8 level, selectable
- Preset Syringe brand: 8, include B-D, B.Braun, Terumo, and 5 Chinese brand; local brand configuration supported
- Language : 11, Chinese, English, French, Russian, Turkish, Portuguese, Polish, Bulgarian, Czech, Romanian
-
ALARM
- VTBI done, VTBI Near done, KVO finish, Syringe empty, Syringe disengaged
- Syringe near empty, occlusion, system error, system abnormal, battery low
- battery empty, reminder, standby, AC power disconnection
-
SAFETY REQUIREMENT
- AC Power: 100 -240 V (50/60Hz)
- Battery Type : Lithium
- Battery Operation Time : Standard ; 6hours @ 5ml. hr ; Optional : 12 hours @ 5ml/h
- Charging time : <5 hours
- Classification: CF, Class I
- IP Grade : IP24
- Temperature : 0 ~ 40°C for operating, -40 ~ 70 °C for storage
- Humidity : 15 ~ 95% for operating. 10 ~ 95 % for storage
- Air Pressure: 57 ~ 106kPa for operating, 50 ~ 106kPa for storage
-
INTERFACE
- Data Interface : Supported, RS232
- Wireless : WiFi (Optional)
- Nurse Call Supported
- DC Input : Supported
- Ambulance : Supported , meet RN 1789 requirement
Packing: 1 UNIT